Security Advisory: CVE-2026-59106
Unauthenticated Remote Code Execution (RCE)
A security vulnerability has been identified in the WolfProt interface implementation. Insufficient neutralization of user-controlled input could allow an unauthenticated attacker with network access to a vulnerable service to execute operating-system commands with the privileges of the affected application service.
WolfProt is the proprietary control protocol used for device management and integration. The vulnerable interface is reachable on the network ports listed below:
- TCP 50915 (WolfProt, unencrypted)
- TCP 50917 (WolfProt over TLS)
- TCP 80 (WebSocket via HTTP)
- TCP 443 (WebSocket via HTTPS)
Potential impacts include:
- Execution of operating-system commands with the privileges of the affected application service.
- Unauthorized access to, modification of, or disruption of data and functions available to that service.
At the time of publication, WolfVision is not aware of active exploitation of this vulnerability.
Affected Devices
- Cynap Pure (Next Gen), Cynap Bridge: Firmware Version < v2.00c
- Cynap Pro, Cynap Core Pro, Cynap Receiver, Cynap Pure, Cynap Pure Mini, Cynap Pure Pro: Firmware Version < v1.78a
- Cynap Videobar, Firmware Version < v1.72e
- Cynap, Cynap Core, Cynap Pure SDM: all firmware versions
The listed devices are affected when a vulnerable service is reachable by an attacker over the network.
Resolution
The vulnerability has been fixed by ensuring that all user-controlled input is passed safely as arguments to system calls and is never interpreted by a shell.
Fixed in
Affected devices should be updated to the following firmware versions as soon as possible:
- Cynap Pure (Next Gen), Cynap Bridge: Firmware Version v2.00c
- Cynap Pro, Cynap Core Pro, Cynap Receiver, Cynap Pure, Cynap Pure Mini, Cynap Pure Pro: Firmware Version v1.78a
- Cynap Videobar, Firmware Version v1.72e
Discontinued models
These models are affected and will receive no firmware fix:
- Cynap
- Cynap Core
- Cynap Pure SDM
No firmware fix is planned for these discontinued models. Decommission them when feasible, or restrict access to the affected services to trusted hosts and networks.
Mitigation
Until an update can be applied, restrict network access to the WolfProt-related ports (TCP 50915 and 50917) as well as the web management interfaces (TCP 80 and 443) to trusted hosts only. Note that these services cannot be disabled.
WolfVision recommends keeping devices up to date and using dedicated, managed network segments (VLAN or firewall zone) to restrict device access to trusted hosts only.
Acknowledgment
We thank the National Test Institute for Cybersecurity (NTC) for responsibly disclosing this vulnerability and for their cooperation throughout the coordinated disclosure process.
Contact
To report security vulnerabilities, please refer to our security policy.
Published: 21 September 2026